Y09-3016 Handheld Laser Particle Counter
This instrument is the company's latest developed handheld laser particle counter using a full semiconductor laser sensor. It can connect to a PC data acquisition system for remote control, allowing direct observation of the instrument's testing status. Test data can be analyzed and processed by a computer and saved as an Excel file. All technical indicators meet the requirements of the JJF1190-2008 verification regulation issued by the National Metrology Administration. The entire machine utilizes U.S. microcomputer control processing technology, semiconductor laser sensor technology, and an imported air pump. It features multiple functions, high measurement accuracy, fast speed, portability, and simple operation. The instrument can simultaneously measure the number of dust particles of multiple particle sizes in a single sample. This product is widely used in cleanroom testing in electronic manufacturing plants; on-site filter testing and leak detection; monitoring of biosafety, HVAC systems, computer rooms, beverage packaging environments, pharmaceutical and medical device production environments, hospital clean operating rooms, automotive spray environments, microelectronics, biochemical products, food hygiene, fine chemicals, precision machinery, aerospace, and other production and research departments. It is the preferred instrument for HVAC and pharmaceutical companies and their regulatory departments to implement GMP standards and for electronic manufacturing plants.
Main Technical Parameters:
Light Source | Semiconductor laser, lifespan greater than 10 years >30000h |
Sampling Flow Rate | 2.83L/min (0.1ft³) |
Counting Efficiency | 0.3μm 50% ±20 0.5μm 100% ±10 |
Particle Size Concentration Indication Error | ±20% |
Particle Size Distribution Error | ±30% |
Maximum Sampling Concentration | 30,000 particles/L |
Display Method | 320×240 high-resolution LCD screen display, Chinese/English interface selection, real-time display, previous cycle display, real-time concentration display, can display time, date, measurement value, temperature and humidity, room number, sampling point, sampling times, battery level, status and other parameters, 95% UCL calculation, can directly display particle concentration (particles/m³) |
Rechargeable Battery | Lithium-ion battery, 16.8 V, 2600mAh. |
Power Supply | AC power adapter, AC: 100V~245 V, 50/60 Hz to DC: 16.8 V, 1 A; |
Operating Time | 8 hours (remaining battery level indication) |
Counting Mode | Cumulative value, difference value, concentration value |
Testing Method | Single, repeat, continuous, calculate, remote |
Unit Conversion | Units can be converted to m³, ft³ |
Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm, six particle sizes counted simultaneously. Optional particle sizes: 0.3μm, 0.5μm, 0.7μm, 1.0μm, 3.0μm, 5.0μm |
Sampling Cycle | 1~9999 (S) Delay counting: 0~99 (S) Self-cleaning time: ≤10 (min) |
Operating Environment | Temperature: 0~40℃ (50~104℉) Relative Humidity: 20~90%RH, no condensation. Atmospheric Pressure: 86-106KPa |
Temperature and Humidity: | Optional (1) Temperature: 0~50℃±1℃. (2) Humidity: 0~100%RH±5% |
UCL Settings | Sampling points (A): 2~9 points setting. Sampling times per point (L): 2~9 times setting Measurement position: 0-999 |
UCL Reports | ISO14644-1, GB50073-2001, new 2010 edition GMP, FS-209E |
Data Storage | Can store 1000 sets of data (circular buffer) (including particle size, data, environmental data, year, month, day, time, sampling volume, data location), data is not lost after power off. |
Communication Interface | RS232, 9600 baud rate |
Alarm Settings | Instrument has level alarm function, can alarm for cleanroom classes 100, 1000, 10000, 100000, 300000, 1000000 when exceeded Low battery voltage alarm |
Zero Count | Complies with JJF-1190-2008 Dust Particle Counter Metrological Calibration Specification and JIS B9921:1997 Less than 1 count per five minutes |
Coincidence Error | 5 %, at 2,000,000 particles per cubic foot |
Printing Function | External printer (optional accessory) |
Dimensions | 23X13X4.5(cm) |
Weight | 0.6kg |
Calibration | JJF-1190-2008 Dust Particle Counter Metrological Calibration Specification traceable to the U.S. National Institute of Standards and Technology (NIST). Our company has passed the national metrology establishment assessment and is traceable to the Shanghai Institute of Measurement and Testing Technology. It can also be calibrated by the user or by a third-party national metrology institution. |
Standard Configuration | Sampling port rubber sleeve, carrying case/charger, isokinetic sampling head, zero filter, USB to RS 232 module, RS 232 connection cable, computer connection communication software CD, user manual, original factory test report, certificate of conformity |
Optional Accessories | External printer, professional tripod sampling stand, temperature and humidity sensor |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 星源洁净 |
| Spec: | Y09-3016 |
| Stock: | |
| Origin: | China / Jiangsu / Suzhoushi |