OPC-3106T High Flow Laser Particle Counter
Contact Info
- Add:苏州市吴江经济开发区江陵街道联兴村渡船桥花苑东区23号, Zip: 215216
- Contact: 高新
- Tel:13776141586
- Email:2319039989@qq.com
Other Products
OPC-3106T High Flow Laser Dust Particle Counter
1. Light Source: Semiconductor Laser
2. Sampling Flow Rate: 28.3L/min, convertible to 8.5L/min, built-in flow sensor, automatic closed-loop flow control
3. Particle Size Channels: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0μm
4. Display: 7-inch Capacitive Touch Screen
5. Power Supply: Rechargeable Lithium Battery 14.8V 9.6A
6, Uses imported DC brushless fan, PWM regulation control
7. Data Storage: Can store 30000 sets of data
8. Printing Function: Thermal Printer
Product Features
This instrument is developed in accordance with the requirements of the new GMP (2010 edition) in collaboration with Nanjing University of Science and Technology and other units.
The product's housing is made of 316L stainless steel. The laser sensor uses a full semiconductor laser and semiconductor
photodiode receiver, ensuring the stability of the light source and the accuracy of the signal receiver. Greatly reduces stray
light in the scattering chamber, improving the sensor's signal-to-noise ratio. Uses LCD liquid crystal touch screen control, making the displayed data clear and operation convenient.
The instrument can automatically determine various cleanliness levels based on customer-selected standards.
Application Range
This product is widely used in medical, pharmaceutical, electronic, chemical, optical, food, cosmetics, biological products, aerospace,
and various testing institutions for dust particle detection.
Main Technical Parameters:
Light Source: Semiconductor Laser, lifespan greater than 10 years>30000h
Sampling Flow Rate28.3L/min convertible to 8.5L/min (1ft³)±5%, can automatically maintain constant flow based on the length resistance of the sampling tube
Display Method155×85mm high-resolution capacitive touch screen, Chinese interface, real-time display, previous cycle display, real-time concentration display,
Can display time, date, measurement value, temperature and humidity, room number, sampling point, sampling times, status, and other parameters, 95% UCL calculation,
Can directly display particle concentration(particles/cubic meter), three-level permission management.
Power Supply/Operating Power Maximum Consumption:20W (1) Built-in long-life lithium battery: Can work continuously for 3.5 hours, external charger can quickly charge, charging
Power supply is 100V~220V, 50/60Hz
Operating Time8 hours
Counting Mode: Cumulative value, difference value, concentration value
Testing Mode: Single, repeat, continuous, calculation, remote,
Unit Conversion: Units can be converted tom³
Particle Size Channels0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0μm
Sampling Cycle1~9999 (S) Delay Count: 0~9999(S)Self-cleaning Time: ≤10(min)
Operating Environment Temperature:0~40℃(50~104℉)Relative Humidity:20~90%RH, no condensation. Atmospheric Pressure: 86-106KPa
Temperature and Humidity: Optional(1)Temperature: 0~50℃±1℃.(2)Humidity: 0~100%RH±5%
UCL Settings Sampling Points(A):2~9 points setting. Sampling Times per Point:(L)2~9 times setting Measurement Position: 0-9999
UCL Report Complies with ISO14644-1 2015, GB/T16292, GMP(2010), FS209E
Data StorageCan store 30000 sets of data (circular buffer)(including particle size, data, environmental data, year, month, day, time, sampling volume,
data port), data is not lost after power off.
Communication InterfaceAB line, 9600 baud rate, USB interface
Alarm Settings: The instrument has level alarm function, can alarm after exceeding standards for cleanrooms 100, 1000, 10000, 300000, 1000000 level, simultaneously
complies with the new GMP standard's A/B/C/D four levels static and dynamic standards measurement, four standard switching measurement
Zero Count Complies with JJF-1190-2008 Dust Particle Counter Metrology Calibration Specification and ISO/FDIS21501-4:2018 less than 1 per five minutes
Coincidence Error5%, 2,000,000 particles/cubic foot
Printing Function: Thermal Printer
Weight4.5kg
Calibration: Can meet JJF-1190-2008 Dust Particle Counter Metrology Calibration Specification, GB/T6167-2007 Dust Particle Counter Performance Test
Method and ISO/FDIS21501-4:2018(E)Cleanroom Light Scattering Dust Particle Counter Calibration Method, traceable to Shanghai
Institute of Measurement and Testing Technology. Can also be calibrated by ourselves or by third-party national metrology institutions, also traceable to the National Institute of
Standards and Technology(NIST). Our company has passed the national metrology establishment assessment, and the company's standard dust particle counter has participated in the national
dust particle counter value comparison organized by provincial metrology institutions, and is used as a standard precision particle counter by relevant metrology testing institutions
during dust particle counter metrology calibration work.
Standard Configuration: Professional Isokinetic Sampling Head, Sampling Stand with Sampling Tube, Built-in Printer, Aluminum Alloy Case, Operation Manual, Factory Test Report, Zero
Count Filter, Charger, Sampling Stand, Printing Paper
Dimensions200*180*180(mm)
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 星源洁净 |
| Spec: | OPC-3106T |
| Stock: | 1000 |
| Manufacturer: | |
| Origin: | China / Jiangsu / Suzhoushi |