APC-3106T High Flow Laser Particle Counter
Contact Info
- Add:苏州市吴江经济开发区江陵街道联兴村渡船桥花苑东区23号, Zip: 215216
- Contact: 高新
- Tel:13776141586
- Email:2319039989@qq.com
Other Products
APC-3106T High-Flow Laser Dust Particle Counter
1. Light Source: Semiconductor Laser
2. Sampling Flow Rate: 28.3L/min, convertible to 8.5L/min, built-in flow sensor, automatic closed-loop flow control
3. Particle Size Channels: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0μm
4. Display: 7-inch capacitive touch screen
5. Power Supply: Rechargeable lithium battery 14.8V 9.6A
6. Uses imported DC brushless fan, PWM regulation control
7. Data Storage: Can store 30000 sets of data
8. Printing Function: Thermal printer
Product Features
This instrument is a successful product developed in collaboration with Nanjing University of Science and Technology and other units, in accordance with the requirements of the new version of GMP (2010 edition).
The product's housing is made of 316L stainless steel. The laser sensor uses a full semiconductor laser and semiconductor photodiode receiver, ensuring the stability of the light source and the accuracy of the signal receiver. It greatly reduces stray light in the scattering chamber and improves the signal-to-noise ratio of the sensor. It uses an LCD capacitive touch screen for control, making the displayed data clear and operation convenient.
The instrument can automatically determine various purification levels based on the standards selected by the customer.
Application Range
This product is widely used in medical, pharmaceutical, electronic, chemical, optical, food, cosmetics, biological products, aerospace, and various testing institutions for dust particle detection.
Main Technical Parameters:
Light Source: Semiconductor laser, lifespan greater than 10 years >30000h
Sampling Flow Rate: 28.3L/min, convertible to 8.5L/min (1ft³) ±5%, automatically maintains constant flow based on the resistance of the sampling tube length
Display Method: 155×85mm high-resolution capacitive touch screen, Chinese interface, real-time display, previous cycle display, real-time concentration display,
can display time, date, measurement value, temperature and humidity, room number, sampling point, sampling times, status, and other parameters, 95% UCL calculation,
can directly display particle concentration (particles/m³), three-level permission management.
Power Supply / Operating Power Maximum Consumption: : 20W (1) Built-in long-life lithium battery: can work continuously for 3.5 hours, external charger can quickly charge, charging
power supply is 100V to 220V, 50/60Hz
Operating Time: 8 hours
Counting Mode: Cumulative value, difference value, concentration value
Testing Method: Single, repeat, continuous, calculation, remote,
Unit Conversion: Unit can be converted to m³
Particle Size Channels: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0μm
Sampling Cycle: 1 to 9999 (S) Delay counting: 0 to 9999 (S) Self-cleaning time: ≤10 (min)
Operating Environment Temperature: 0 to 40℃ (50 to 104℉) Relative Humidity: 20 to 90%RH, no condensation. Atmospheric Pressure: 86-106KPa
Temperature and Humidity: Optional (1) Temperature: 0 to 50℃ ±1℃. (2) Humidity: 0 to 100%RH ±5%
UCL Setting Sampling Points (A): 2 to 9 points setting. Sampling times per point: (L) 2 to 9 times setting Measurement location: 0-9999
UCL Report Complies with ISO14644-1 2015, GB/T16292, GMP (2010), FS209E
Data Storage: Can store 30000 sets of data (circular buffer) (including particle size, data, environmental data, year, month, day, time, sampling volume,
data port), data is not lost after power failure.
Communication Interface: AB line, 9600 baud rate, USB interface
Alarm Setting: The instrument has a level alarm function, can alarm after exceeding the standards for clean rooms 100, 1000, 10000, 300000, 1000000 level,
simultaneously complies with the new GMP standard's A/B/C/D four levels static and dynamic standards measurement, four standards switch measurement
Zero Count: Complies with JJF-1190-2008 Dust Particle Counter Metrology Calibration Specification and ISO/FDIS21501-4:2018, less than 1 per five minutes
Overlap Error: 5%, at 2,000,000 particles/cubic foot
Printing Function: Thermal printer
Weight: 4.5kg
Calibration: Can meet JJF-1190-2008 Dust Particle Counter Metrology Calibration Specification, GB/T6167-2007 Dust Particle Counter Performance Test
Method and ISO/FDIS21501-4:2018 (E) Cleanroom Light Scattering Dust Particle Counter Calibration Method, traceable to Shanghai
Institute of Measurement and Testing Technology. It can also be calibrated by itself or by a third-party national metrology institution, and is also traceable to the National Institute of Standards and Technology (NIST). Our company has passed the national metrology establishment assessment, and the company's standard dust particle counter has participated in the national dust particle counter value comparison organized by provincial metrology institutions, and is used as a standard precision particle counter by relevant metrology and testing institutions for dust particle counter metrology calibration work.
Standard Configuration: Professional isokinetic sampling head, sampling stand with sampling tube, built-in printer, aluminum alloy case, operation manual, factory test report, zero
count filter, charger, sampling stand, printing paper
Dimensions: 200*180*180 (mm)
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 星源洁净 |
| Spec: | APC-3106T |
| Stock: | 10000 |
| Manufacturer: | |
| Origin: | China / Jiangsu / Suzhoushi |